Get the filter order right
Installing or replacing a UF inline water filter starts with matching the cartridges, flow arrows and connection ports. Use this guide to compare the illustrated 4-stage and 5-stage layouts, identify the separate UF flush connection and plan your replacement.
Check your model first. These diagrams apply to the systems shown. Follow the labels and instructions supplied with your purifier if its layout or fittings differ.
Before you start
1. Isolate the supply. Turn off the incoming water and release pressure through the filtered-water tap before disconnecting tubing.
2. Record the connections. Take a clear photo and label the tubes so each one returns to the correct port.
3. Check compatibility. Match the cartridge type, fittings and flow direction. Keep a towel or container ready for residual water.
Watch the installation video
Use the existing video alongside the diagrams below. Identify your own cartridge labels and port markings before making any connection.
Choose the matching filter sequence
Trace the tubing from the incoming supply to the filtered-water tap. Cartridges can face opposite directions, so their physical left-to-right position alone does not show the flow order.
4-stage: PP → CTO → UF → T33
Water supply → PP sediment filter → CTO carbon block → UF membrane → T33 post-carbon filter → tap. This layout has no separate UDF cartridge.
4-stage connection diagram. The UF drain outlet is a separate branch; the filtered outlet connects to T33.
5-stage: PP → UDF → CTO → UF → T33
Water supply → PP sediment filter → UDF granular activated carbon → CTO carbon block → UF membrane → T33 post-carbon filter → tap. UDF sits between PP and CTO.
5-stage connection diagram. Follow each arrow and connecting tube to distinguish the main water path from the UF flush branch.
Identify the three UF connections
The illustrated UF membrane has two connections at the inlet end and a filtered-water outlet at the opposite end.
UF inlet: receives pre-filtered water from CTO.
Filtered-water outlet: connects to T33, then to the tap.
Drain/flush outlet: the extra side port beside the inlet, labelled “Drain Outlet” in the diagrams. Direct flushing water from this port safely to waste.
For the manual-flush arrangement shown: use compatible tubing and a suitable shut-off valve on the flush port. Keep that valve closed during normal filtration. Open it only for flushing as directed by the filter instructions, then close it again. The flush port does not supply the drinking-water tap.
Connect the cartridges step by step
1. Arrange the cartridges. Select the matching 4-stage or 5-stage diagram and check every flow arrow.
2. Connect the main water path. Follow the sequence from the supply through the cartridges to the tap. Keep the UF flush branch separate.
3. Seat each tube securely. For compatible push-fit fittings, use a clean, square, undamaged tube end. Push to the internal stop, gently pull back to check retention and refit any original locking clip.
4. Support the assembly. Return the cartridges to their holders. Route tubing without sharp bends or strain on the fittings.
5. Restore water and flush. Reopen the supply slowly, check each connection for leaks and flush according to the purifier and cartridge instructions. Turn the supply off and release pressure before adjusting a leaking connection.
See the cartridges in place
These photos show installation examples. Your cartridge positions may differ from the diagrams; always follow the labelled connections.
Example installation: inline cartridges secured in holders with connecting tubes inside a purifier cabinet. Trace the tubing to confirm the flow order.
Closer view of the PP, UDF and CTO pre-filter cartridges. Use the labels and flow arrows when identifying each stage.
Replacing an existing cartridge
Turn off the supply and release pressure first. Replace one cartridge at a time, following your reference photo and preserving the original flow direction. For a standard push-fit tube connection, remove any locking clip, press the release ring against the fitting and pull the tube straight out. Do not force a locked or unfamiliar fitting.
Follow the quick-connect replacement photo guide for the matching removable connectors. For replacement planning, read when to change your water filter.
Check before returning to use
Leaks: check every disturbed fitting after restoring the supply.
Low or no flow: confirm the supply valve is open, tubing is not kinked and cartridge arrows follow the correct route.
UF flush valve: return it to its normal position after flushing, as specified for your model.
Cloudy water: see why water may look cloudy after a filter change for guidance.