Water Knowledge
How to Install an RO Water Purifier
INSTALLATION GUIDE · REVERSE OSMOSIS
A practical guide to installing your RO system
Installing an RO water purifier starts with the right filter order, properly seated seals and carefully connected tubing. This guide follows the assembly sequence for a conventional five-stage, under-sink system with three pre-filter housings, an RO membrane, a storage tank and a T33 post-carbon filter.
Fittings, port positions, pumps and flushing procedures vary by model. Follow the labels and instructions supplied with your own unit. If your purifier has a different design, ask Aqua Cares Cambodia to confirm the connections before opening the water supply.
Before you start
- Check that the purifier, compatible cartridges, membrane, tank, faucet, feed adapter, drain connection and tubing are complete and undamaged.
- Choose a clean, accessible position with room below the housings for future filter changes. Keep the unit and tank supported and away from heat.
- Prepare a towel, bucket, housing wrench, suitable spanners and a tubing cutter. Use thread-sealing tape only on connections that require it.
- Turn off the cold-water supply. Keep the tank valve closed and open the drinking-water faucet to release any remaining pressure. Disconnect power if the system has a pump.
- Wash your hands and keep the inside of housings, tubing ends and cartridge sealing surfaces clean.
Use cold water only. Check your model’s permitted feed pressure, temperature and electrical requirements. Ask an installer for help with drilling, unfamiliar plumbing or electrical work. Never open a housing while it is under pressure.
Know the water connections
The three pre-filters treat incoming water before it reaches the RO membrane. The membrane has separate purified-water and wastewater outlets. Purified water supplies the storage tank and passes through the T33 post-carbon filter on its way to the drinking faucet. Wastewater goes to the drain through the system’s flow restrictor.
Reference layout for a conventional five-stage RO system. Use the port labels on your own unit; tubing colours and port positions may differ.
Do not guess from tubing colour. Identify the water inlet, tank, faucet and drain connections. Keep factory-fitted check valves, automatic shut-off components and the wastewater flow restrictor in their intended positions.
Under-sink pipework and assembly steps 1–3
This diagram shows the under-sink pipework layout and the first three assembly steps: 1. fit the PP, UDF and CTO pre-filter cartridges; 2. install the RO membrane; 3. fit the storage-tank valve. Trace the cold-water feed, drinking-water faucet, tank and drain connections against your own unit’s labels. Follow the detailed steps below, including the housing seal checks and gentle tank-valve tightening.
1. Install the pre-filters: PP → UDF → CTO
Raw water → PP sediment filter → UDF granular activated carbon → CTO carbon block → RO membrane
Remove all protective wrapping from each cartridge. Place the PP filter in the first housing reached by the incoming raw water, UDF in the second and CTO in the third. Centre each cartridge on its locating points and follow any direction markings on the cartridge.
In this front-view photo, raw water enters the PP/PPF housing on the right, then passes through UDF in the middle and CTO on the left.
Check every housing seal before tightening
Inspect the seal ring (O-ring) on each pre-filter housing before you screw it back on. The ring must be present, clean, undamaged and seated evenly in its groove, without twisting, pinching or trapped debris. Check that the cartridge is centred and no packaging remains inside.
Check the black seal ring around the housing rim. Remove the cartridge’s plastic protective wrap before installation.
A good seal comes from a correctly seated O-ring, not excessive force. Start the housing by hand so the threads engage straight. Tighten according to your model’s instructions, using the supplied housing wrench only as directed. Do not force a housing that will not seat. Replace a damaged or missing ring before use.
2. Fit the RO membrane
Check whether the membrane is already installed. If it is supplied separately, keep the water and power off, open the membrane housing and remove the membrane’s protective packaging just before fitting it. For the membrane shown in the supplied guide, the end with two small black O-rings goes in first. Push it fully into its seat without damaging the seals.
Inspect the membrane-housing cap seal as carefully as the pre-filter seals. Refit it in the correct groove, close the cap without cross-threading and reconnect any tube removed for access. Use only a lubricant approved for drinking-water seals if lubrication is specified; do not use household petroleum grease.
Membrane insertion and housing seal reference. Confirm the insertion direction against the membrane and housing supplied with your unit.
Before sending water through a new membrane: follow your model’s pre-filter rinsing procedure so loose carbon particles are not carried into it. If a separate pre-filter flush is required, have the installer complete it at the specified connection before final membrane commissioning. Do not improvise a bypass or run a pump dry.
3. Install the storage-tank valve gently
Check that the tank outlet and valve threads are clean and undamaged. Follow the supplied valve’s sealing method. If thread-sealing tape is required, apply it neatly to the male thread without covering the opening; do not add tape to push-fit tubing connections.
Start the tank valve straight on the threaded outlet and tighten gently by hand.
Do not overtighten the RO tank valve. Too much force can crack the valve or damage the threaded connection. Do not force it to face a particular direction or use a wrench for extra leverage unless the manufacturer specifically requires it. If it leaks, isolate and depressurise the system, then inspect the seal and threads.
Leave the tank’s air valve and factory pre-charge alone during normal installation. Keep the water valve closed until the commissioning procedure calls for it to be opened.
4. Fit the feed adapter, faucet and drain connection
Cold-water feed adapter
With the cold supply turned off and pressure released, fit the compatible feed adapter at the cold-water connection. Use the washers or thread seals specified for that fitting. Keep its small RO shut-off valve accessible and closed while you complete the installation. Do not connect the purifier to the hot-water line.
Drinking-water faucet
Use a suitable existing opening where possible. If drilling is needed, check the sink or countertop material and the space below it before work begins. Fit the faucet washers, gasket and retaining nut in the order supplied with that faucet. Secure it without stressing the countertop or overtightening the mounting nut.
Wastewater drain connection
Use a drain connection compatible with the purifier and local plumbing requirements. For a conventional drain saddle, choose an approved position on the sink drain above the trap, align the saddle opening and gasket with the drilled hole, and secure it evenly. Keep the drain tube clear of kinks. Air-gap faucets require their own drain routing; ask an installer if you are unsure.
Accessory reference: cold-water feed adapter, faucet mounting parts and drain saddle. Use the instructions for your actual fittings.
5. Connect and secure the tubing
- Trace each connection using the unit’s labels: cold-water feed to inlet, purified-water tank port to tank valve, post-carbon outlet to drinking faucet, and wastewater outlet to drain.
- Cut compatible tubing squarely with a clean cutter. Remove damaged, crushed or scratched ends.
- Push the tube fully into each quick-connect fitting, past the internal seal, then pull back gently to check it is secure.
- Refit the locking clip where supplied. Route tubes without sharp bends, tension or contact with hot surfaces.
To disconnect: shut off the feed and tank, release pressure, remove the locking clip, press the collet inward and pull the tube straight out.
For more connector photos, see our quick-connect inline filter guide.
6. Start slowly, check for leaks and flush
- Confirm that all cartridges and the membrane are fitted, every housing seal has been checked, and all tubes and clips are secure.
- Follow your model’s start-up valve positions. Open the cold-water feed slowly and check every housing, tank valve, adapter and tubing joint for leaks. Restore power to a pump-equipped unit only as its instructions require.
- Complete the specified pre-filter, membrane and post-carbon flushing procedure. Keep commissioning water out of drinking use.
- Fill and drain the storage tank as required by the manufacturer before using the water for drinking or cooking. The required flush time and number of tank fills depend on the model; do not assume they are the same for every purifier.
- Recheck with the faucet open and again after the tank fills and the system reaches normal pressure. Confirm that the system stops producing wastewater after its normal shut-off cycle.
If you find a leak: close the water inlet and tank valve, disconnect power if fitted, and open the drinking faucet to release pressure before adjusting any connection. Do not try to cure a leak by tightening a pressurised housing harder. Stop using the purifier until the problem is resolved.
Keep the shut-off valves accessible and check the installation again later the same day and the following day. Persistent leaks, unusual pump cycling, no purified water or continuous drain flow after the tank is full need attention from an installer.
Watch the installation references
Use these videos as visual references alongside the written steps. Your purifier’s manual, port labels and supplied fittings take priority if the model shown is different.
RO installation reference
Open the RO installation reference on YouTube at 5:25.
Older model reference — discontinued product
The product shown in the next video is discontinued. Use it only to understand general assembly techniques; its components and connections may differ from your current system.
Keep your purifier easy to maintain
Record the installation date and filter types. Replacement intervals depend on your water quality, usage and the cartridge instructions. Read when to change your water filter and keep enough clearance to remove each housing without straining the tubing.
Need help with your RO installation?
Send Aqua Cares Cambodia a clear photo of your purifier, its model label and the connection you need help with. Our team can help identify the correct arrangement and discuss installation support.
CHAT ON TELEGRAM